HVAC Systems Treatment

CLT-300 is a liquid blend of Molybdate/Borate corrosion inhibitors designed to control pitting and corrosion in closed hot water and chilled systems. It will protect all metals in a closed system, including sweated copper lines, from corrosive attack. CLT-300 is a Nitrite Free formula, making it resistant to biological degradation.

 

It is also specially formulated to handle high temperature hot water systems.

 

USES

 CLT-300 functions as a protective film-forming corrosion inhibitor and scale suppressant. It helps to keep systems clean and free from corrosive attack and harmful insulating deposits, thereby maintaining design heat transfer efficiency and longer equipment life.

CLT-300 remains effective at temperatures up to 200F (see dosage recommendation on reverse side). It does not affect nonmetallic materials in cooling systems and it is compatible with glycol-based antifreezes.

DESCRIPTION

 

Appearance................. Water white to pale amber

pH ................................................................ 10.9

Weight .............................................. 9.36 lb./gal.

 

 Feature

Advantage

Benefit

Molybdate/Borate Blend

Inhibits corrosion by forming a protective film on metal surfaces.

Resistant to bio attack.

Protects system surfaces from corrosion. Extends equipment life.

Tolyltriazole

Inhibits corrosion of copper surfaces by forming a thin protective film.

Provides copper corrosion inhibition. Improves and increases overall corrosion control.s

Antiscalant Qualities

Keeps system clean and free of heat adsorbing sludge and mineral scale deposits.

Insures optimum heat transfer and maximum fuel efficiency. Reduces maintenance time.

Temperature Stable

Remains effective up to 200F.

Highly effective corrosion and scale inhibition obtained under varying conditions.

Compatible With Ethylene Glycol Based Antifreezes

Used in both chilled and hot water closed loop systems.

One product for all closed loop systems. Economical.

Concentrated Formulation

Effective corrosion and scale control obtained at low dosages.

Economical. Low use-cost.

CLT-300

Molybdate Based Pitting and Corrosion Inhibitor for Closed Hot/Chilled Water Systems

 Dosage and feeding

Add a minimum of two to three gallons for every 1000 gallons of water in the system.  More CLT-300 is required as water temperature and hardness increases.  See Chart below for guidance. Your Water Energy Representative will make specific recommendations required by your system as determined by periodic water analysis.

CLT-300  (gallons/1,000

gallons system Volume)

Mo Residual

System Conditions

2.5

60 ppm - 80 ppm

Large with excellent control

5.0

120 ppm - 160 ppm

Small to medium up to 120oF

6.4 - 9.6

200 ppm - 300 ppm

125oF - 200oF

NOTE: Oxygen is required for Mo to work as a corrosion inhibitor, which is why higher dosages are required at higher temperatures.

 

Calcium Hardness

CLT-300 (Gallons/1000 Gallons System Volume)

0

Same as chart above

100

Same as chart above x 1.3

200

Same as chart above x 1.7

300

Same as chart above x 2

NOTE: Calcium will precipitate Mo, which is why a higher dosage is required in hard water systems.

 

NOTE: Dirty/contaminated systems should be drained, flushed and/or chemically cleaned before treatment to get maximum results.

 NOTE: Dirty/contaminated systems should be drained, flushed and/or chemically cleaned before treatment to get maximum results.

 FOR HANDLING AND PRECAUTIONARY INFORMATION, REFERENCE THE PRODUCT LABEL AND MATERIAL SAFETY DATA SHEET.

PACKAGING